Why will be the threads G 1/8 and 1/8 NPT offered for pressures only to a nominal pressure range of 400 bar? Where does this limit come from?
Basically, the explanation is simple: From the certain pressure limit, the thread flanks are no more ?strong? enough to resist the force of the applied pressure. If the pressure is too much, there is a risk of shearing for the thread. Incidentally, Launch result from DIN EN 837-1.
Attention: The maximum pressure up to which a thread can be utilized depends not merely on the thread diameter, but additionally on the selected sealing type and the material of the counter-thread.